Analysis of Multiple Causes and Solutions for False Open Circuit in PCB Flying Probe Testing
Category: Industry News
Release Date: 2022-04-21
Summary: With the rapid development of the PCB industry, testing equipment is continuously updated technologically, and the market demands higher stability and efficiency from testing equipment. To maximize the stability of testing equipment, human involvement plays a crucial role in ensuring the equipment is stable, reliable, and efficient. During testing, false open circuit phenomena are inevitable, especially when there are many false opens (≥10). Operators and process personnel should pay attention and analyze and resolve issues from the perspectives of equipment, process data, and printed circuit board products. Based on my experience in equipment maintenance and related process feedback analysis, this article takes the Italian Seica series PCB flying probe testing as an example to summarize the causes and solutions for frequent false open circuits in PCB flying probe testing equipment, for reference and discussion among peers. 1. Determining if the issue is caused by equipment instability The simplest way to determine if the equipment is working properly is to test with previously qualified old file data and corresponding qualified PCB boards (after removing surface oxides, etc.). If open circuits still appear, it should be an equipment fault; otherwise, it is likely a process data or PCB issue. When equipment problems occur, use the following methods for inspection and analysis. 1) Software maintenance First, run the equipment's maintenance (also called self-test) software according to prompts to check for damaged components or errors. If damaged components or errors are found, replace the corresponding parts and calibrate according to error prompts. Second, use the DMC software to check if the feedback system of each axis is working properly. The correct operation steps are: minimize the test system → open DMC (Start\Program\DMC) or from the desktop (DMC TEST interface appears) → press the emergency stop switch → manually move each axis and observe the digital changes and sensitivity of each axis's grating feedback system, checking if the numbers change within the specified range; then activate TESTXY.DMC and TESTZ.DMC → RUN and observe if each axis can return to zero (each axis position reading is '0'). 2) Hardware faults Hardware faults are more likely among all faults because the quality of the testing system is closely related to the working environment (temperature, humidity, etc.), working hours, maintenance, and other factors. Based on my summary, hardware faults include the Z-axis linear motor, grating ruler, grating feedback data line connectors, and L-type probes. (1) Z-axis linear motor: Due to long-term, high-frequency operation, the motor's moving parts can become blackened with grime, causing stiffness and increased motor load. Therefore, the linear motor should be removed and cleaned with anhydrous alcohol approximately every 6 months. Care must be taken during removal and cleaning to avoid losing guide rail balls. (2) Grating ruler: The grating ruler is the core component for positioning in all high-precision equipment, directly affecting equipment accuracy and stability. However, most gratings suffer from poor environments or air sources, with workshop dust accumulating on the grating surface, which affects feedback signals and causes frequent open circuits. To remove dust, clean the grating with anhydrous ethanol using fine gauze gloves (dipped lightly in anhydrous alcohol) with gentle one-directional wiping; avoid back-and-forth or excessive force to prevent scratching. The air source must be dried, oil-filtered, and water-filtered before entering the equipment to avoid affecting equipment lifespan and measurement accuracy. (3) Grating data feedback line connectors: PCB flying probe testing equipment moves quickly, causing strong vibrations during operation. The grating data line connectors may become loose due to inertia after some use. To prevent this, check all plugs before powering on each day. (4) L-type probes: Probe condition is also a key factor causing open circuits, mainly due to probe tip dullness, poor contact between probe and connector, and regular calibration (at least once per week). Replace probes when dull, reset usage count after replacement, regularly check for looseness between probe and connector, and ensure automatic calibration at least once a week. 2. Process data conversion Errors in new file process data generation are also causes of open circuits. Many process personnel make mistakes during CAM data conversion, often due to inconsistent hole or pad attributes across layers or surfaces. When this occurs, process personnel must repeatedly review the data files. 3. Printed circuit board product issues If equipment and process data issues are excluded, the problem likely lies with the PCB product itself, mainly manifested as warpage, solder mask, or character irregularities. (1) Warpage: Some production schedulers skip the hot air leveling process to save time and send boards directly for final inspection. Without hot leveling, warpage may exceed the allowable range of the testing equipment. Therefore, hot leveling is essential, and inspectors should measure warpage before testing. (2) Solder mask: Products with severe open circuits often have partially blocked through-holes by the solder mask layer, leading to unsatisfactory test results. Testing should avoid via holes (or ensure via continuity) as much as possible. (3) Characters: Many PCB manufacturers print characters before electrical testing. Slight misalignment or low precision of character films can partially cover fine surface mount pads and small holes. To avoid open circuits caused by characters, PCBs with fine surface mount pads, small holes (Φ<0.5), and fine-line high-density patterns should be electrically tested before character printing. The causes of false open circuits in electrical testing are multifaceted but generally fall into the above three categories. To quickly identify the problem, specific and comprehensive analysis should be conducted according to the situation to improve efficiency. Source: PCB Talent Network
With the rapid development of the PCB industry and continuous technological updates in testing equipment, the market demands higher stability and efficiency from testing devices. To maximize the stability of testing equipment, human factors play a crucial role in ensuring the equipment is stable, reliable, and efficient. During testing, false open circuit phenomena are inevitable, especially when there are many false opens (≥10). Operators and process personnel should pay attention and analyze and resolve issues from the equipment, process data, and printed circuit board products. Based on my practical work in equipment maintenance and related process feedback analysis, this article takes the Italian Seica series PCB flying probe test as an example to summarize the causes and solutions for frequent false opens in PCB flying probe testing equipment, for reference and discussion among peers.
1. Determine if caused by equipment instability
The simplest way to determine if the equipment is working properly is to test using previously qualified old file data and corresponding qualified PCB boards (with surface oxides removed). If open circuits still appear, it should be an equipment fault; otherwise, it is likely a process data or PCB issue. When equipment problems occur, use the following methods for inspection and analysis.
1. Software maintenance
First, run the equipment's maintenance (also called self-test) software according to prompts to check for damaged parts or errors. If damaged parts or errors are found, replace the corresponding parts and calibrate according to the error prompts.
Next, use the DMC software to check whether the feedback systems of each axis are working properly. The correct operation steps are: minimize the test system → open DMC under (Start\Program\DMC) or on the desktop (DMC TEST interface appears) → press the emergency stop switch → manually move each axis and observe the digital changes and sensitivity of each axis's grating feedback system, checking if the numbers change within the specified range; then activate TESTXY.DMC and TESTZ.DMC → RUN to observe whether each axis can return to zero position (each corresponding axis position reading is '0').
2. Hardware faults
Hardware faults are more likely among all faults because the quality of the testing system is closely related to the working environment (temperature, humidity, etc.), working hours, maintenance, and other factors. Based on my summary, hardware faults include the Z-axis linear motor, grating ruler, grating feedback data line connector, and L-shaped probe.
(1) Z-axis linear motor: Due to long-term, high-frequency operation, the motor's moving parts can become blackened with grime, causing stiffness and increased motor load. Therefore, the linear motor should be removed and cleaned with anhydrous alcohol regularly (about every 6 months). Care must be taken when removing and cleaning to avoid the guide rail balls falling off.
(2) Grating ruler: The grating ruler is the core component for positioning in all high-precision equipment, and its quality directly affects the equipment's accuracy and stability. However, most gratings are affected by poor environment or air source quality. Workshop environments may cause excessive dust on the grating ruler surface, which directly affects feedback signals and leads to frequent open circuits. To remove dust, clean the grating ruler with anhydrous ethanol using fine gauze gloves (dipped lightly in anhydrous alcohol) in a single direction gently. Do not scrub back and forth or apply excessive force (to avoid scratching the grating). Also, the air source must be dried, oil-filtered, and water-filtered before entering the equipment; otherwise, it will affect the equipment's lifespan and measurement accuracy.
(3) Grating data feedback line connector: PCB flying probe testing equipment moves quickly, and the whole machine vibrates strongly during operation. Therefore, the grating data line connector may become loose due to inertia after some use, causing poor contact with the socket. To avoid this, check all plugs before powering on each day.
(4) L-shaped probe: The quality of the probe is also an important factor causing open circuits. Issues include probe tip dulling, poor contact between probe and probe plug, and regular calibration (at least once a week). When the probe tip is dull, it must be replaced, and after replacement, reset the usage count and regularly check for looseness between the probe and probe tip, ensuring automatic calibration at least once a week.
2. Process data conversion
Errors in new file process data generation are also a cause of open circuits. Many process personnel make mistakes when converting CAM data, generating incorrect netlist files. Most errors are due to inconsistent hole or pad attributes across layers or sides. Therefore, when such issues occur, process personnel must repeatedly review the data files.
3. Printed circuit board product issues
If testing equipment and process data issues are excluded, the problem likely lies with the PCB product itself, mainly manifested as warpage, solder mask, and irregular characters.
(1) Warpage: Some production schedulers skip the hot air leveling process to save time and send products directly to final inspection. Without hot leveling, the product's warpage exceeds the allowable range of the testing equipment. Therefore, the hot leveling process is indispensable, and inspection personnel should measure warpage before testing.
(2) Solder mask: Products with severe open circuits often have partially blocked through-holes by the solder mask layer, resulting in unsatisfactory test results. Testing should avoid transition holes (or ensure hole conductivity is correct).
(3) Characters: Many PCB manufacturers print characters before electrical testing. If the character position is slightly offset or the character film precision is insufficient, fine surface mount pads and small holes may be partially covered by characters. To avoid open circuits caused by characters, PCBs with fine surface mount pads, small holes (Φ<0.5), and fine line high-density should follow the process of electrical testing before character printing.
The causes of false open circuits in electrical testing are multifaceted but generally fall into the above three categories. To quickly identify the problem, specific and comprehensive analysis should be conducted according to the actual situation to improve efficiency.
Source: PCB Talent Network
Keywords: Analysis of Multiple Causes and Solutions for False Open Circuit in PCB Flying Probe Testing
Related News
Company News
-
Congratulations on the launch of Hubei Longteng Electronics Technology Co., Ltd. website!
Release time:2022-06-01
-
In winter, Hubei Longteng Electronics and the Xiaochang County Trade Union visited the Wangdian Welfare Home in Xiaochang to greet the elderly living alone.
Release time:2021-10-01
-
Successful conclusion! Two projects totaling 8.5 billion, Fushan Industrial Park brings more good news!
Release time:2020-12-24
-
Hubei Longteng Electronics 2019 Year-End Fire Drill
Release time:2019-12-18
-
Our company offers the guidance course "Fundamentals of Electronic Technology"
Release time:2019-11-18
-
Our company organized a fire drill for all employees
Release time:2019-11-05
-
Opening Ceremony of the New Apprenticeship System for Schools and Enterprises
Release time:2019-11-05
-
Safety conditions and safety production management are the essence of production and business units.
Release time:2019-10-22
-
Warm congratulations on the Longteng product certification and other certificates
Release time:2019-09-21
-
The 2019 Hubei Longteng Spring Festival Gala began on January 21, 2019
Release time:2019-02-13
-
Establishment of the Collaborative Innovation Center for Electronic Application Technology
Release time:2018-11-17
-
February 2018: Progress of Longteng Phase II Project
Release time:2018-11-10
-
The First Congress of Female Employee Representatives and the Inaugural Election Meeting of the Women's Committee
Release time:2018-10-28
-
Hubei Provincial Government Official Website and Hubei Daily Special Report on Longteng Electronics
Release time:2018-10-20
Industry News
-
Analysis of Multiple Causes and Solutions for False Open Circuit in PCB Flying Probe Testing
Release time:2022-04-21
-
Inquiry into the Management of PCB Innovation
Release time:2022-04-21
-
GALAX launches new RTX 2070/2080 Super EX graphics cards: pink color scheme/lighting
Release time:2022-04-21
-
The PCB industry urgently needs AI and machine learning
Release time:2022-04-21
-
Digital Era: Apple Will Use Ultra-Thin Rigid Printed Circuit Boards (PCB) to Manufacture Micro LED Devices in the Future
Release time:2021-11-01
-
Gigabyte released the first batch of Z490 series motherboards to support the 10th generation Intel desktop Core processors
Release time:2020-10-13
-
Profit-taking leads to a pullback in the PCB sector
Release time:2020-10-13
-
Emerging Flexible Electronics Technology
Release time:2020-10-13
Previous: No more!